The valve comes with a knob for a possible manual actioning, signalling also an “open or close” status.
The installation is advised where a minimum dripping is accepted.
Technical features (see material compatibility with respect to chemicals substances)
Shutter type: Plates on conical seat
Threading: GAS cylindrical 55° UNI- ISO 228
Room temperature range: from 0 °C to 100 °C max
Actuator working pressure range: min. 5 bar, max. 10 bar
Actuator: single acting normally closed
Cylinder material: Aluminum 2011 alloy anodized
Shaft material: stainless steel AISI 303
Valve body material: Brass OT-58
Shutter material: Brass OT-58
Material in contact with the product: brass 58, Aluminum N° 2011 alloy anodized, AISI 303 and NBR
Tips for installation
We advise to pack the threadings with liquid packing, or to use gaskets to avoid an excessive stress on the threadings when closing.
In case the valve intercepts a product which could sediment, it is advisable to position the valves on vertical pipes. Please avoid positioning the valve with the knob downwards in order to prevent sediments stagnations in contact with the gaskets.
Make sure the valve is lubricated by the pneumatic system.
Checks to be carried out after a usage period
The valve comes with a safety hole signaling the possible bad functioning of the sealing gaskets separating the actuator from the intercepted products. Please check the efficiency of these O-Rings through the above-mentioned hole every 3000/4000 operations.
Every time the actuator is unscrewed from the valve body check the right positioning and the gasket status before assembling the valve.
Attention: in case of maintenance, pay attention to the cylinder opening as inside there is a compressed spring.